CUBITI CONTROLFLEX 1-R ultra
ARSŁ/1-R/U
 
ARTICLE'S CHARACTERISTIC

Redressing apparatus for upper limb is made of:
  1. Two open sleeves - for the arm and forearm part - enabling their easy installation and exact adjustment to sizes of upper limb's measurements.
  2. Orthopedic splints with fixing system.
  3. VELCRO stickers.
The device is equipper with uniaxial side splints made of high quality plastic armed with carbon fibre. The system of splints in the apparatus and their specific flexibility result in proper adherence to the upper limb and also enable to stabilize the cubital joint excellently. Splints are provided with regulation range. The angle of bend and unbend can be adjusted every 15°. Such precise regulation of the device facilitates the process of rehabilitation of damaged cubital joint. Splint assure side stabilization of the limb. There is also installed a system of fixing to arm sleeve and forearm sleeve. It enables to attach the splints to the soft part of the apparatus in an individual, easy and precise way. VELCRO system positions the device and assures adherence of the apparatus to the limb and effective stabilization of the joint. Additionally, there are soft cushions installed inside the hocks to protect elbow from injuries.

ATTRIBUTES
  1. Doskonała stabilizacja - dzięki zastosowaniu dwóch zespołów szyn ortopedycznych uzyskano doskonałą stabilizację wyrobu.
  2. Komfort użytkowania - dzięki zastosowaniu do wykonania rękawów dzianiny nie występują podczas użytkowania wyrobu otarcia naskórka.
  3. Łatwość użytkowania - prosty sposób zakładania i zdejmowania wyrobu przez pacjenta.
  4. Utrzymanie właściwej higieny - ze względu na łatwość zdemontowania wyrobu nie ma problemu z jego praniem i konserwacją.




PURPOSE:
Should be applied in cases of:
  • contracture of bend and unbend of cubital pond,
  • instability of elbow after injuries,
  • in cycle of convalescence after fractures,
  • after operations (orthopaedy).

CONTRAINDICATION:
Should not be applied in cases of:
  • fresh wounds
  • attritions of skin
  • skin eczemas
  • skin allergies
  • varicosity
  • ulceration of shin

USAGE:
Rehabilitation, orthopaedics, neurology, neurosurgery, rheumatology.

HOW TO PUT IT ON:

INFORMATION FOR PATIENTS:
  1. It should be applied in compliance with indications and under doctor's supervision.
  2. For the first time should be established by doctor or by trained medical staff.
  3. Orthosis should not be used if any ointment or warming up gel had been applied earlier.
  4. It is recommended to use the article together with stocking or antivaricose knee-length socks of minimum compression.
  5. Inappropriate use of article or choosing wrong size can bring about a defect of venous and arterial circulation, trauma of protected joint, skin illnesses etc.
  6. Lack of everyday personal hygiene or inappropriate preservation and washing the article can cause skin attritions or can bring about allergic reactions connected with intensive perspiration and development of bacterial flora.
HOW TO PUT IT ON - SCHEMATIC DIAGRAM:

MAINTENANCE:
  1. Hand-wash in warm water and soap in 30 deg. temperature
  2. Do not iron
  3. Do not use chlorine
  4. Dry far from the sources of heat
Attention: before washing remove the splints together with the system of their assembly.

Type of used side splint
Adjustment of the angle of bending and straightening of the joint


MATERIALS:
Dzianina , szyny ortopedyczne, pasy VELCRO, klamerki poliamidowe, płyta polietylenowa.

The Class I Medical Device - in compliance with the Council Directive (93/42/EEC) on medical devices. The manufacturer issued the appropriate EC Declaration of Conformity.  More >>
 
Lenght of shoulder and forearm
S - A:12,5 / B:14
M - A:14 / B:19
L - A:14 / B:23,5

 OFFER 
Adults
Neck section of the spine
Chest section of the spine
Loins and lower back section of the spine
Hip joint
Shoulder joint
Elbow joint
Wrist/Hand
Knee joint
Ankle joint
Children
Chest section of the spine
Knee joint
Other orthopaedic products
Armpit crutch
Patient lifting belt

 ISO 


An ISO 9001:2000 and ISO 13485:2003 quality management system has been implemented in the company encompassing.....

 Cooperation 


  2005-2008 © ART-REH Sp. z o.o.
Designed by: Marcin Betleja  
 
All pictures, materials and trade marks presented on this web site exclusively belong to ART-REH Sp. z o.o.
Reproduction or copying strictly forbidden without prior permission of the owner.